International Journal of Medical Biochemistry - Int J Med Biochem : 9 (4)
Volume: 9  Issue: 4 - 2026
RESEARCH ARTICLE
1. Systemic inflammatory and immunonutritional profile in women with low anti-Müllerian hormone levels
Oznur Dundar Akin, Naile Fevziye Misirlioglu, Hafize Uzun
doi: 10.14744/ijmb.2026.35492  Pages 201 - 209
INTRODUCTION: Anti-Müllerian hormone (AMH) is widely used as a biomarker of ovarian reserve. Although systemic inflam-mation and nutritional status may be associated with ovarian function, the relationships of composite inflammatory and nutrition-related indices with low AMH remain incompletely characterized. This study aimed to evaluate systemic inflammatory and nutrition-related indices in women with low AMH levels.
METHODS: A total of 150 women were included, comprising 75 women with low AMH and 75 with high AMH. The neu-trophil-to-lymphocyte ratio (NLR), platelet-to-lymphocyte ratio (PLR), systemic immune-inflammation index (SII), sys-temic inflammation response index (SIRI), aggregate index of systemic inflammation (AISI), prognostic nutritional index (PNI), and hemoglobin–albumin–lymphocyte–platelet (HALP) index were evaluated. Associations between continuous AMH concentrations and these indices were assessed using Spearman correlation analysis. Age- and body mass index (BMI)-adjusted logistic regression models were used to evaluate associations with low AMH.
RESULTS: Women with low AMH were older than those with high AMH (33.0 [29.5–36.5] vs. 27.0 [24.0–31.0] years; q<0.001), whereas BMI did not differ significantly between the groups. AISI, SIRI, PLR, NLR, and SII were significantly higher, whereas PNI and HALP were significantly lower, in the low AMH group, with all differences remaining significant after multiple-comparison correction. AMH was inversely correlated with AISI (ρ=-0.282), SIRI (ρ=-0.266), PLR (ρ=-0.257), NLR (ρ=-0.314), and SII (ρ=-0.324), and positively correlated with PNI (ρ=0.466) and HALP (ρ=0.366) (all p≤0.001). After adjustment for age and BMI, higher NLR was associated with greater odds of low AMH (adjusted OR=2.03, 95% CI: 1.34–3.06; p<0.001), whereas higher PNI was associated with lower odds (adjusted OR=0.31, 95% CI: 0.19–0.51; p<0.001).
DISCUSSION AND CONCLUSION: Low AMH was associated with a profile of higher systemic inflammatory indices and lower nutrition-re-lated indices. These associations remained significant after adjustment for age and BMI, supporting an association be-tween low AMH and a distinct systemic inflammatory and immunonutritional profile. Further prospective, multicenter studies are needed to confirm these associations and clarify their biological and potential clinical significance.

2. Clinical and laboratory correlates of low fecal elastase-1 levels: A retrospective analysis
Neziha Hacihasanoglu Cakmak, Gozde Ulfer, Pakize Yigit, Turkan Yigitbasi, Gulbanu Canbaloglu Erkan
doi: 10.14744/ijmb.2026.25338  Pages 210 - 216
INTRODUCTION: Fecal elastase-1 (FE-1) is widely used as a noninvasive, stool-based test to evaluate pancreatic exocrine function. This study compared radiological and laboratory findings between patients with low and normal FE-1 levels and investigated variables independently associated with low FE-1 levels.
METHODS: The records of 1,133 patients who underwent FE-1 testing were retrospectively reviewed. Patients were clas-sified into normal (≥200 µg/g, n=961) and low (<200 µg/g, n=172) FE-1 groups. Group comparisons and multivariable logistic regression analyses were performed. To assess the incremental discriminative contribution of pancreatic am-ylase while avoiding confounding due to differences in sample size, four additional models were evaluated using the same complete-case subset (n=396). Areas under the receiver operating characteristic curves (AUCs) were compared using paired DeLong tests in jamovi version 2.6.2.0.
RESULTS: Low FE-1 levels were more frequent among patients with pathological radiological findings than among those with normal findings (31.7% vs. 12.1%; χ²=45.2, p<0.001; OR=3.38, 95% CI: 2.33–4.89). Among the same 396 complete cases, Model A (age, sex, and radiology) yielded an AUC of 0.694 (95% CI: 0.619–0.769). Adding pancreatic amylase (Model B) increased the AUC to 0.727 (95% CI: 0.657–0.798), although this increase was not statistically significant (ΔAUC=0.0333; DeLong p=0.100). Model C (age, sex, radiology, ALT, glucose, BUN, IgA, and lipase) yielded an AUC of 0.740 (95% CI: 0.672–0.807). Adding pancreatic amylase (Model D) increased the AUC to 0.766 (95% CI: 0.705–0.827), but the increase was not statistically significant (ΔAUC=0.0264; DeLong p=0.107).
DISCUSSION AND CONCLUSION: Low FE-1 levels were associated with radiological, metabolic, nutritional, and laboratory abnormalities. Pancreatic amylase was independently associated with low FE-1 levels in the expanded regression model; however, its incremental contribution to AUC was not statistically significant when the models were compared using data from the same patients. These findings reflect factors associated with low FE-1 levels and should not be interpreted as establish-ing a diagnostic model for exocrine pancreatic insufficiency (EPI).

3. Comparability of adrenocorticotropic hormone measured in spray-dried K2-EDTA and spray-dried K3-EDTA tubes
Yasemin Ustundag, Muhammed Said Karaca, Kagan Huysal, Furkan Erdogan
doi: 10.14744/ijmb.2026.72473  Pages 217 - 222
INTRODUCTION: Blood samples for adrenocorticotropic hormone (ACTH) tests are collected in dipotassium or tripotassi-um ethylenediaminetetraacetic acid (K2-EDTA or K3-EDTA) tubes. The interchangeable use of spray-dried K2-EDTA and K3-EDTA tubes may occasionally occur in practice and is appropriate only if both tube types yield comparable analytical results. Therefore, this study aimed to evaluate the interchangeability of these tubes for ACTH measurement.
METHODS: Seventy-two volunteers were included in the study. From each participant, K2-EDTA and K3-EDTA blood samples were collected simultaneously. ACTH was measured by chemiluminescent immunoassay on a Maglumi X3 analyzer (SNIBE, Shenzhen, China). The Wilcoxon signed-rank test, Passing-Bablok regression, Mountain plot, and Bland-Altman analyses were used to evaluate differences between measurements.
RESULTS: The median ACTH concentration in K2-EDTA tubes was 35.1 pg/mL (10.35–107.16) [7.73 pmol/L (2.28–23.60)] and in K3-EDTA tubes was 32.96 pg/mL (9.85–99.90) [7.26 pmol/L (2.17–22.00)]. The Wilcoxon signed-rank test (z=-7.14, p<0.001) demonstrated a statistically significant difference between the results. In the Bland-Altman analysis, the mean difference between the two samples was determined to be 1.49 pg/mL (0.33 pmol/L). Lin’s concordance correlation coefficient was 0.989 (95% CI: 0.984–0.993), indicating good agreement between ACTH results obtained from the two tubes. Mountain plot analysis demonstrated that most differences clustered around zero, with an asymmetric right tail suggesting the presence of larger differences in a limited number of samples.
DISCUSSION AND CONCLUSION: ACTH concentrations measured in both tubes are proportional, and the results obtained from K2-ED-TA and K3-EDTA tubes support analytical comparability within the ACTH concentration range evaluated in this study. However, complete interchangeability between the results of the two tube types cannot be assumed in all clinical scenarios; further studies are needed in subjects with higher ACTH levels.

4. End-user verification of the Maccura F810 hematology analyzer: A comparison with Mindray BC-6200
Havva Yasemin Cinpolat, Muserref Hilal Sehitoglu Bingol
doi: 10.14744/ijmb.2026.50470  Pages 223 - 231
INTRODUCTION: Analytical performance verification is essential before implementing hematology analyzers in routine clin-ical practice. This study aimed to evaluate the performance characteristics of the Maccura F810 hematology analyzer.
METHODS: This study was conducted at the Medical Biochemistry Laboratory of Çanakkale Onsekiz Mart University Hospital between January and April 2023. Analytical performance was verified by evaluating precision (within-run and between-batch), carry-over, and linearity in accordance with the Clinical and Laboratory Standards Institute and the International Council for Standardization in Hematology guidelines. Additionally, 356 K2-EDTA samples from patients were used for comparative analysis with the Mindray BC-6200, including Passing-Bablok regression, Bland-Altman anal-ysis, and bias estimation at medical decision points. We compared the results with the manufacturer's claimed per-formance specifications and further evaluated them using state-of-the-art (SOTA) and minimum biological variation (MBV) performance criteria.
RESULTS: All precision results met the manufacturer's performance specifications, whereas only monocyte, eosinophil, and basophil counts exceeded the SOTA precision limits at certain concentration levels. Carry-over was negligible for white blood cell count, red blood cell count, hemoglobin, and platelet count. Linearity was confirmed across the con-centration ranges specified by the manufacturer. Bland-Altman analysis showed agreement with the manufacturer's specifications and SOTA criteria for all parameters, while all parameters except monocyte count also fulfilled the MBV criteria. Predicted bias at predefined medical decision points was within the MBV and SOTA limits for all evaluated pa-rameters, except for platelet count at 50 ×10⁹/L, where the predicted bias was 8.00% (95% CI, 3.21%-12.89%), exceeding both the MBV (7.5%) and SOTA (6.4%) limits.
DISCUSSION AND CONCLUSION: Overall, the Maccura F810 demonstrated satisfactory analytical performance and is suitable for routine clinical laboratory use, despite higher CVs observed for a limited number of parameters and a predicted PLT bias at 50 ×10⁹/L that exceeded both acceptance criteria.

5. Interpretation of heterophile-blocking tube results in thyroid function testing using analytical change limits: An exploratory study of clinically discordant cases
Rana Turkal, Ali Yaman, Tulay Cevlik, Hulya Gozu, Onder Sirikci, Goncagul Haklar
doi: 10.14744/ijmb.2026.92170  Pages 232 - 241
INTRODUCTION: This study aimed to evaluate an analytical framework for interpreting heterophile-blocking tube (HBT) results in thyroid function tests (TFTs) by comparing HBT-associated changes in thyroid-stimulating hormone (TSH), free thyroxine (fT4), and free triiodothyronine (fT3) with analyte-specific analytical change limits (ACLs), documenting transitions across laboratory reference intervals, and comparing changes across the three analytes measured in the same treated aliquot.
METHODS: This single-center, prospective, exploratory observational study enrolled 41 adults whose TFT results were discordant with their clinical presentations. Untreated and HBT-treated aliquots of the same serum specimen were analyzed in the same run. Signed percentage changes were compared with ACLs of ±2.77 × the analytical coefficient of variation (CVa) (12.47% for TSH, 15.84% for fT3, and 14.40% for fT4), and paired concentrations were compared using the Wilcoxon signed-rank test with Holm adjustment. Changes in the three analytes from the same treated aliquot were compared, and the sensitivity of the classification to the imprecision estimate was examined.
RESULTS: Median signed changes were -0.45% for TSH, -6.47% for fT3, and -2.11% for fT4; only fT3 showed a significant paired reduction (adjusted p=0.0038). The ACL was exceeded in 8/41 (19.5%) fT3, 1/39 (2.6%) TSH, and 2/41 (4.9%) fT4 results. The rates of TSH and fT4 exceedance were close to those expected from analytical variation alone (p=0.86 and p=0.61, respectively), whereas fT3 exceeded the limit approximately four times more often (p=0.0008). fT3 changes showed no significant correlation with concurrent changes in TSH or fT4, clustered in specimens with elevated pre-HBT fT3 levels, and remained more frequent at every assumed CVa ranging from 1.8% to 8%. Threshold-supported normal-ization occurred in four fT3 results and in none of the TSH or fT4 results.
DISCUSSION AND CONCLUSION: An imprecision-based ACL combined with reference-interval transition provides a transparent criterion for HBT interpretation. HBT-responsive changes occurred predominantly in fT3, whereas TSH and fT4 in the same aliquots were largely unaffected, arguing against a nonspecific pretreatment effect. A change exceeding the ACL is compatible with, but does not by itself prove, heterophile antibody interference and should be interpreted together with the com-plete thyroid profile, the clinical context, and, where necessary, independent confirmatory testing.

6. Internal validation and explainability of machine learning models for abnormal liver biochemistry
Osman Demir, Muzaffer Katar, Omer Faruk Nasip
doi: 10.14744/ijmb.2026.22599  Pages 242 - 250
INTRODUCTION: To develop, internally validate, and interpret machine learning models for classifying abnormal liver bio-chemistry using routine biochemical parameters.
METHODS: This retrospective study included 335 individuals classified according to ICD-coded diagnoses retrieved from the hospital information system, comprising 175 individuals in the non-disorder group and 160 individuals in the ab-normal liver biochemistry group. Aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase, gam-ma-glutamyl transferase, total bilirubin, direct bilirubin, international normalized ratio, and albumin levels were used as predictors. Nine supervised learning models were evaluated using 10×5 repeated stratified cross-validation. The model with the numerically highest mean ROC-AUC was further examined using out-of-fold calibration analysis, exploratory decision curve analysis, and SHAP-based explanations.
RESULTS: Aspartate aminotransferase showed the highest mean individual ROC-AUC (0.832), followed by alanine ami-notransferase (0.796). XGBoost showed the numerically highest mean ROC-AUC (0.9640, 95% CI 0.9615–0.9664), with a mean accuracy of 0.9215 and F1-score of 0.9157. Mean sensitivity, specificity, positive predictive value, and negative predictive value were 0.9019, 0.9394, 0.9333, and 0.9161, respectively. Calibration analysis based on averaged repeated out-of-fold predictions yielded a Brier score of 0.056. SHAP analysis identified international normalized ratio, aspartate aminotransferase, and albumin as the most influential contributors to model predictions for the ICD-defined abnormal liver biochemistry outcome.
DISCUSSION AND CONCLUSION: XGBoost showed high internally validated classification performance for the ICD-defined abnormal liver biochemistry outcome. These findings should be interpreted as internally validated classification performance rather than definitive clinical diagnostic accuracy. Although the outcome was based on ICD-coded diagnoses rather than biochemical threshold rules, external validation using independently adjudicated clinical outcomes remains necessary.

7. Specimen type as the dominant predictor of pre-analytical rejection in the emergency department: An explainable machine-learning (SHAP) analysis
Yunus Goren, Hakan Ozerol
doi: 10.14744/ijmb.2026.79106  Pages 251 - 263
INTRODUCTION: Preanalytical specimen rejection is a leading source of laboratory errors in emergency departments, but most evidence comes from small studies lacking a true denominator. We examined factors associated with specimen rejection in a complete 34-month cohort and assessed the extent to which apparent predictability was attributable to specimen type.
METHODS: All tubes collected in the emergency department of a tertiary hospital between October 2023 and August 2026 were included. The outcome was tube rejection. Predictors were restricted to information available at the time of request: patient characteristics, timing (including hours since shift handover), workload, collection context, specimen type, and panel size. Four algorithms were compared using temporal validation on tubes collected between January and August 2026 and evaluated for discrimination, calibration, net benefit, subgroup performance, and Shapley addi-tive explanations. Adjusted odds ratios (ORs) were calculated using standard errors clustered by presentation.
RESULTS: Of 1,190,944 tubes collected during 404,247 presentations, 37,633 (3.16%) were rejected, with hemolysis ac-counting for 67.6% of rejections. LightGBM achieved an out-of-time area under the receiver operating characteristic curve (AUROC) of 0.780 (95% confidence interval [CI], 0.775–0.785), with a calibration slope of 0.983. Biochemistry tubes had an adjusted OR of 10.48 (95% CI, 10.05–10.93). Specimen type alone achieved an AUROC of 0.709, whereas all patient characteristics, timing, and workload variables combined achieved an AUROC of 0.601. The odds of rejection were highest during the final 4 hours of the 24-hour shift (OR, 1.15; 95% CI, 1.09–1.21). The lower unadjusted odds ob-served in pediatric and obstetric units were no longer evident after adjustment.
DISCUSSION AND CONCLUSION: Specimen type was the strongest predictor of rejection. Models developed using laboratory information system data reflect differences in specimen mix and should be benchmarked against specimen type.