ISSN  2587-2362  |  E-ISSN  2618-642X
pdf
Internal validation and explainability of machine learning models for abnormal liver biochemistry [Int J Med Biochem ]
Int J Med Biochem . 2026; 9(4): 242-250 | DOI: 10.14744/ijmb.2026.22599

Internal validation and explainability of machine learning models for abnormal liver biochemistry

Osman Demir1, Muzaffer Katar2, Omer Faruk Nasip3
1Department of Biostatistics, Tokat Gaziosmanpasa University Faculty of Medicine, Tokat, Türkiye
2Department of Biochemistry, Tokat Gaziosmanpasa University Faculty of Medicine, Tokat, Türkiye
3Department of Medical Education and Informatics, Tokat Gaziosmanpasa University Faculty of Medicine, Tokat, Türkiye

INTRODUCTION: To develop, internally validate, and interpret machine learning models for classifying abnormal liver bio-chemistry using routine biochemical parameters.
METHODS: This retrospective study included 335 individuals classified according to ICD-coded diagnoses retrieved from the hospital information system, comprising 175 individuals in the non-disorder group and 160 individuals in the ab-normal liver biochemistry group. Aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase, gam-ma-glutamyl transferase, total bilirubin, direct bilirubin, international normalized ratio, and albumin levels were used as predictors. Nine supervised learning models were evaluated using 10×5 repeated stratified cross-validation. The model with the numerically highest mean ROC-AUC was further examined using out-of-fold calibration analysis, exploratory decision curve analysis, and SHAP-based explanations.
RESULTS: Aspartate aminotransferase showed the highest mean individual ROC-AUC (0.832), followed by alanine ami-notransferase (0.796). XGBoost showed the numerically highest mean ROC-AUC (0.9640, 95% CI 0.9615–0.9664), with a mean accuracy of 0.9215 and F1-score of 0.9157. Mean sensitivity, specificity, positive predictive value, and negative predictive value were 0.9019, 0.9394, 0.9333, and 0.9161, respectively. Calibration analysis based on averaged repeated out-of-fold predictions yielded a Brier score of 0.056. SHAP analysis identified international normalized ratio, aspartate aminotransferase, and albumin as the most influential contributors to model predictions for the ICD-defined abnormal liver biochemistry outcome.
DISCUSSION AND CONCLUSION: XGBoost showed high internally validated classification performance for the ICD-defined abnormal liver biochemistry outcome. These findings should be interpreted as internally validated classification performance rather than definitive clinical diagnostic accuracy. Although the outcome was based on ICD-coded diagnoses rather than biochemical threshold rules, external validation using independently adjudicated clinical outcomes remains necessary.

Keywords: Artificial intelligence, biomarkers, cross-validation studies, liver function tests, machine learning, ROC curve


Corresponding Author: Osman Demir, Türkiye
Manuscript Language: English
×
APA
NLM
AMA
MLA
Chicago
Copied!
CITE
LookUs & Online Makale